Age-related macular degeneration (AMD) and diabetic retinopathy (DR) are the leading causes of blindness in the elderly worldwide. Current treatments, while effective, are not ideal in terms of delivery nor monitoring. Standard administration methods for therapeutics include the use of standard 30 gauge needles and syringes.

The team has developed a prototype injector-extractor device (SERID) that safely administers therapeutic injections into the eye to ensure maximum efficacy and improved safety. SERID will be the world’s first custom designed one-off use instrument for the eye environment. At the same as the single injection, the device can obtain a sample of the gel-like vitreous within the eye which could hold important pre-functional protein biomarkers and could further guide and tailor treatment regimens for individual patients. With its needle-within-a-needle design, the shaving action is able to remove a small amount of vitreous safely from the eye, thereby allowing for a small amount of space where therapeutics can be injected. This reduces the intraocular pressure spike, which in turn reduces the amount of drug that is refluxed after the needle is withdrawn, which is a problem in current methods of injection. Overall, SERID enables more accurate drug delivery.

Coupled with a novel minute volume protein analyser that is under co-development by the team and an industry partner, the small sample (<10uL) of vitreous obtained can be analyzed to determine the concentration of pre-functional protein biomarkers. Such information can potentially guide individualized treatment of the patient before vision is compromised. Together, SERID and the analysis platform can help tailor treatments for AMD/DR patients, resulting in a reduction of unnecessary treatments, visits, and added cost savings to patients.

Project Deliverables

The refinement of the beta prototype which will include finalization of the SERID design, taking into account human and ergonomics considerations and testing on appropriate models.


Principal Investigator: Dr Marcus ANG

Institution: Singapore Eye Research Institute

NHIC Ref: NHIC-I2D-1604104

 

 

See all MEDTECH projects >

A Force Sensor to Deliver Optimal Cricoid Pressure for Airway Protection

Cricoid pressure refers to the finger pressure applied over the cricoid cartilage on the neck dur...

An In-office Trachealesophageal Puncture, Prosthesis Sizing and Insertion Device

Total laryngectomy involves the removal of a patient’s voice box and results in the loss of voici...

Modular Endoprosthesis for Mandible Reconstruction

Mandible defects may result from trauma, inflammatory diseases or upon tumour resection. The gold...

Assay for Early Detection of Flares in Patients with Systemic Lupus Erythematosus

Systemic Lupus Erythematosus (SLE) is an autoimmune condition which affects multiple organ system...

Novel inhibitors for Natural Killer/T-cell lymphoma (NKTCL)

The Natural Killer/T-cell lymphoma (NKTCL) is a subtype of Non-Hodgkin’s lymphoma (NHL) which is...

Swellable Drug Loaded Stent Coating for Ureteral Stricture

Ureteric strictures result from fibrosis in the wall of the ureter, resulting in narrowing of the...